  1. 1.Standard drywall thickness for walls:

    • A.1/4"
    • B.1/2" (12.7mm)✓
    • C.5/8"
    • D.3/4"

    Why: 1/2" for walls. 5/8" for ceilings and fire-rated. 5/8" Type X = 1-hour fire rating.

  2. 2.Interior door rough opening width for 2'-8" door:

    • A.2'-8"
    • B.2'-10" (door + 2" for jamb/shims)✓
    • C.3'-0"
    • D.2'-6"

    Why: RO = door width + 2" (1" each side). Height = door height + 2-1/2".

  3. 3.R-value measures:

    • A.Temperature
    • B.Thermal resistance of insulation✓
    • C.Moisture resistance
    • D.Structural strength

    Why: Higher R = better insulation. Code minimums: R-20-28 walls, R-40-60 attics in Canada.

  4. 4.Wet area tile substrate should be:

    • A.Regular drywall
    • B.Cement board or waterproof membrane system✓
    • C.Plywood only
    • D.OSB

    Why: Cement board or Kerdi/RedGard provides waterproof, dimensionally stable substrate for shower tile.

  5. 5.Inside corner crown moulding joint:

    • A.Butt joint
    • B.Coped joint✓
    • C.Mitre only
    • D.Glue only

    Why: Coped joints stay tight as wood shrinks. One piece into corner, other coped to profile shape.

  6. 6.Air barrier vs vapour barrier:

    • A.Same thing
    • B.Air barrier stops air movement; vapour barrier stops moisture diffusion — both needed✓
    • C.Only one needed
    • D.Neither needed

    Why: Air leakage carries more moisture than diffusion. Both are needed for proper building envelope performance.

  7. 7.Acoustic insulation in interior walls:

    • A.Increases R-value only
    • B.Reduces sound transmission (increases STC rating)✓
    • C.Only for fire code
    • D.Only exterior walls

    Why: Batt insulation absorbs sound energy. STC increases from ~33 (empty) to ~45+ (insulated).

  8. 8.Baseboard is installed:

    • A.Before painting
    • B.After wall painting, before or after flooring depending on type✓
    • C.Before drywall
    • D.Before framing

    Why: After wall painting. Before carpet, after hardwood/laminate (sits on top with gap hidden).

12 more Interior Finishing questions inside

Plus a timed 403A exam simulator, spaced-repetition review of every question you get wrong, and an AI tutor you can ask “why?”.

Start free — 20 questions a day →